Activity

Reply by ramonruiz

HI Marco, we need more to do more deep analysis. 1.- please more details of motor. 2.- type of load , is it constant or variable?, belt...
ramonruiz

Reply by MARCO20002000

Mr. Ramón: The bearings failed the 24/01/19 and the last vibration data was the 26/12/18. Attached file with the different vibration...

Reply by ramonruiz

Mr. Marco Im looking with more details the vibration reading date.. can you say us the failure date. In september 2018 spectrum , we can...
ramonruiz

Reply by MARCO20002000

Mr. Ramón: Good morning, thanks for your reply; What I have tried to say, is that the bearings failed because they had no grease...

Reply by ramonruiz

Try to work directly from Ascent software.. after send folder to scout..
ramonruiz

Reply by ramonruiz

Dear Marco, The word failure in Ball bearings depends of severity (amplitude) and kind or frequencies appeared in spectrum, the spectrum...
ramonruiz

Reply by shot

Only way I have used is from the route screen, highlite the route push the bottom left hand button and follow the directions. I have...
shot

Reply by ramonruiz

Dear, at All. I had similar experience before with vertical motor, subharmonics peaks appeared when the shaft was moving up and this...
ramonruiz

Reply by Rotating Guy

I notice at motor ob vertical the waveform is looks like modulating for me, the reason why i want to see the picture of pump is to check...
Rotating Guy

Reply by mohiuddin

Ok.I will share to you.....Pump bushes are replaced 4 days before the high vibration observed, so less chance of it.

Reply by Dave Reynolds

http://www.albest.com.tw/news/vb7.pdf vB7 manual page 89 Editing or Deleting a Route Route creation, editing and deletion is carried out...

Reply by Rohit02

Plots are confusing. Motor outboard Vertical shows some beating phenomenon while inboard Vertical or any other point on motor does not...

Reply by Rotating Guy

Can you share the picture of the pump? i want to verify the piping and the structural condition. What i mean in getting the phase is for...
Rotating Guy

Reply by BONI 2

May be too late to post but could be a reference for someone to address 208-P communication problem. The computer that offers built in...

Reply by aziz58

dear jhon pls give me your idea about my post that you can find it by searching Unexpected high vibration sgt 600gas turbine thanks in ...

Reply by mohiuddin

Yes shurafa is right, measured phase didnot show any fault relating identification(for 0.75X), rather I saw the phase shown on CSI is...

Reply by Shurafa

I missed to comment on this in my last post. The common meaning of phase is associated with a shaft position at certain conditions such...
Shurafa

Reply by mohiuddin

Right!! 2250 cpm is not possible..... Can you give e any hint about external vibration source: the equipment is mounted on the vessel...