Respected All,



Pl find attached file for PH Fan Vibration Spectrum, Water Plot Last 7 Vibration reading and Overall Vibration Readings.

Equipment Detail:

Fan Running RPM is 796  DE and NDE Bearing: 22234C/C3/W33. Both Bearing have Oil Lubricated with External Force.



Observation:

1). Spectrum Analysis order show 1X, 1.3X , 1.6X , 2X , 2.3X , 2.6X ,……etc.