Reply to "Vibration at 5X NDE AND DE V for Centrifugal Pump"

WSS

Many styles of centrifugal pumps, can you add more detail

Most of the time, pumps have 2-3 bearings/shaft/impeller/coupling. So if you truly have a 5x peak synchronous to machine running speed and you have 5 vanes on the impeller, then it is vane pass. Bearings will be non-synchronous data

I also see what appears to be harmonics of vane pass, did you change impeller size recently, is there a check valve or valve in general that is stuck or not working properly?

Just by "overhauling" a pump does not mean it can not have vane pass.......

×
×
×
×