Tagged With "Broken Shaft"

Reply

Re: Rotor broken bars problem, is it right?

Walt Strong ·
Cando, This is a very interesting case history, but I would like to understand the sequence of events. Did you remove the motor rotor after conducting the motor current spectrum analysis? If not, what was the reason for removing it? Did the motor current spectrum reveal eccentricity after the motor was reassembled with the damaged rotor or before it was removed? During the installation of the damaged rotor to put it back into service, I would assume that the following would have been...
Reply

Re: Rotor broken bars problem, is it right?

Lampard Nguyen ·
Hello, Rotor was fall when we disassembled motor for replacing bearings and visual inspection of rotor also. It is only time based maitenance for this motor. But, unlucky, rotor was crasked. Current Signature analysis (both of rotor broekn bars FFT and eccentricity FFT which I attached above) is performed after maitenace to ensure motor can run with this rotor for ordering new rotor delay. Of course, we will monitor this motor operation by MCSA and vibration analyis. Firstly, we will do...
Reply

Re: Rotor broken bars problem, is it right?

Howard Penrose ·
Cando Had you performed MCSA prior to this condition being found? It is often the case in cast aluminum rotors that casting voids exist that would cause the low level rotor bar (PPF) frequency that you are seeing. Some manufacturers have more prevalent cast rotor voids than others based upon their casting process. If that is the case and you are not seeing torsional issues, then you are probably OK. The notching in the rotor in this size machine most likely is not an issue as you have a...
Reply

Re: Broken tooth symptoms in Gear box

John from PA ·
A B2SV10 is a double reduction gearbox with the 1st reduction being a bevel set and the 2nd reduction being a helical set. The "translation" of the model number is as follows: B = bevel helical 2 = two stages S= solid shaft V = vertical 10 = size ( not necessarily ratio ) The catalog indicates that the ratio can range from 6.271 to 13.683. The exact ratios available are 6.271, 6.875, 8.000, 8.842, 10.157, 11.045, 12.662 and 13.683. The repetition rate of the fault is 0.085 sec/cyc = 11.76...
Reply

Re: Broken tooth symptoms in Gear box

vidya Sagar ·
Hi john, Thanks for the information. We opened the gearbox recently and found that one of the gear teeth in bevel gear(intermediate shaft) is having pitting.
Topic

Broken Gear Shaft

Jenish ·
Dear Experts, Can anybody give any expert opinion about this Broken Shaft? It is from a stand gearbox of a rolling mill..
Topic

Rotor broken bars problem, is it right?

Lampard Nguyen ·
Dear Experts, Could you please give me some advise about this photos, Is it rotor broken bars problem? I performed current signature analysis test for this motor. In my opinion, there is pole pass frequency peaks with low amplitude. Thank you so much! Regards,
Reply

Re: Rotor broken bars problem, is it right?

edisonindia ·
It's a aluminum die cast rotor. Not really sure what your third picture shows. If you have the test equipment, you could do a growler test.
Reply

Re: Rotor broken bars problem, is it right?

electricpete ·
First photo shows gouge in end ring. That could be the cause of the pole pass sidebands. Second photo shows gouge on od of bore. I look for something to judge the size of the gouge. I think the gouge shown in photo 2 is also shown in the third photo just above 26 (between 2 and 6). It doesn't appear to have penetrated to a bar. So I think it is confined to the bridge area above the bars. 3rd photo - I assume that white flash is just a reflection (maybe the photo is taken through a clear...
Reply

Re: Rotor broken bars problem, is it right?

electricpete ·
Now I'm seeing the sideband was around 53 db below the main peak? Normally I start getting really interested at 45db. What load was that? Was there any trend?
Reply

Re: Rotor broken bars problem, is it right?

Walt Strong ·
I am trying to understand the motor current spectrum. The dominant frequency is near 45 Hz which is not common 50 Hz or 60 Hz line frequency. So was the measurement made with the motor running with VFD at reduced speed and therefore at reduced load? Did you calculate the pole-pass sideband frequency and identify it on the plot? The interpretation of side-band amplitudes may be inconclusive, if the measurement was made at reduced speed and load. I had made a diagnosis of induced draft fan...
Reply

Re: Rotor broken bars problem, is it right?

Shurafa ·
Nice photos. I like these clear pictures. Regards-Ali M. Al-Shurafa
Reply

Re: Rotor broken bars problem, is it right?

edisonindia ·
If the motor was not having any issues like stalling, overcurrent, current oscillation or excessive temperatures, I would run it. pete It is not cost effective to repair die cast rotors. Best to replace them, if found defective. I had replaced a few die cast rotor windings with copper for a set of 6.6 KV motors about 2 decades back, but that was a special case since the OEM had gone bust and the client was desperate.
Reply

Re: Rotor broken bars problem, is it right?

Lampard Nguyen ·
Hello, Thank so much for all recommendation. Some information about this case: - Motor is driven by VSD with line frequency supplies to motor is 45.1 Hz. - Motor has been running with 67% FLA. - Rotor was fall when maintenance, It caused some incisions on rotor which you can see on my photos. We don't have any spare part to replace for motor. Therefore, motor must run with crashed rotor. So, we want to perform MCSA for diagnostic rotor condition. With this result, I think there is not bad...
Reply

Re: Rotor broken bars problem, is it right?

electricpete ·
I agree, based on: 1 - Apparently you have run the motor since the damage to take the current signature. 2 - You have a vsd, so the rotor doesn't see the severe duty of direct on line start. 3 - you are planning to continue monitoring. If you see an increasing trend in sideband under similar conditions that might be a time to be concerned. If damage occurred while stationary, I'm curious what created the mark around the circumfence of rotor at that location. Maybe the od got dinged and...
Topic

Broken tooth symptoms in Gear box

vidya Sagar ·
Hi Friends, In one of the gearbox am finding symptoms of broken tooth(Correct me if am wrong). Gearbox Make: Flender Type :B2SV10 Input RPM :1489 Gearbox Ratio:1:10 I doesn't have teeth details of the gearbox.Please find the time wave form and acceleration spectrum.Vibration levels are less than 2 mm/sec at Gearbox in all directions. Thanks in advance Regards Sagar
Reply

Re: Broken tooth symptoms in Gear box

Walt Strong ·
John, Great analysis with not much to start with! Walt
Reply

Re: Broken tooth symptoms in Gear box

Rao Shahbaz ·
Re: Broken tooth symptoms in Gear box
Reply

Re: Broken tooth symptoms in Gear box

Akhil Rathore ·
superb
Reply

Re: Broken tooth symptoms in Gear box

vibramac ·
Well done John, you cannot bet experience!!!!!!
Reply

Re: Broken tooth symptoms in Gear box

John from PA ·
Thanks for the positive comments!
Topic

Shaft Fracture Demineralized Pump

Hatop Hendra PS ·
Dear Master, I have some problem recently with demineralized pump. This pump shaft suddenly broken when weekly changeover schedule start (16 March 2019). This Pump have good vibration result (no alarm point). and running good after i do shaft alignment at 28 February 2019. Anyone have experience with shaft fracture analysis? What is the possibility problem happen causing shaft broken? Here is the Pump Spec : Centrifugal Pump Brand : Dalian Songlone Pump Q = 40 m3/h H = 50 m Speed = 2930 RPM...
Reply

Re: Shaft Fracture Demineralized Pump

Dave Reynolds ·
The shaft has been welded in the past to build up shaft to repair the key area. Shaft material does not chip off, it will fracture or twist off. The poor key fit, the brittle shaft from welding, radius missing for step in shaft, coupling fit all contributed to the shaft failing Dave
Reply

Re: Shaft Fracture Demineralized Pump

Becar ·
Have you any idea about the reason for key groove damage? If this happened before the shaft broke, you could have some torsional vibration issue. Some parts of the shaft slice also show possible torsional source. How long have you been monitoring and aligning this pump? Is it possible that the initial damage began before your measurements?
Reply

Re: Shaft Fracture Demineralized Pump

Hatop Hendra PS ·
I did not check the keyway condition. Like i said before, the pump running well before alignment. The pump align by dial during project, and this the first time alignment correction with laser alignment. The coupling type is single disc coupling. Monitoring by myself around 8 month, previously by O & M service contractor.
Reply

Re: Shaft Fracture Demineralized Pump

Hatop Hendra PS ·
Thank you Dave. Can you show in the picture where is the welding point?
Reply

Re: Shaft Fracture Demineralized Pump

Hatop Hendra PS ·
Is it possible i do missalignment during shaft alignment? But pump running for 2 weeks after alignment, and vibration result good. I trying my best to align the shaft, prevent offset missalignment, because type of coupling is single disc coupling (handle angular missalignment only)
Reply

Re: Shaft Fracture Demineralized Pump

Walt Strong ·
Photo-3 right side and photo-4 bottom appear to have a material flaw well below the surface. I don't know how long the machine ran after the shaft sleeve repair, but any amount of time was fortunate; even with low vibrations. You could have a metallurgist look at broken shaft, but why pay the money for that? A single disk shaft coupling for that application is unusual, so can you show a photo or OEM link to the product? Vibration measurements in the X-Y-Z lateral directions are not very...
Reply

Re: Shaft Fracture Demineralized Pump

Hatop Hendra PS ·
Thank you Walt. Off course company doesn't want to pay more for analysis (small machine). We just simply fabricate new shaft. And for the disc coupling, already made a PR for tyre coupling, which is more easier to align & maintain. I'm just curious and want some 2nd opinion. For welding or shaft lining history, i do not check, because it's under O & M contractor before, and running well. That's why i want to find out.
Reply

Re: Shaft Fracture Demineralized Pump

Hatop Hendra PS ·
Here is the pump picture Walt. And there is some mark of touching at the wear ring & impeller. How do you think?
Topic

Rotor broken bars?

Lampard Nguyen ·
Dear Experts, We have a squirrel cage inductance motor, 400V VFD, 220KW. The load is Roll which driven by Gear-box in Paper factory. We carried out MCSA and Vibration analysis for this motor. The opposition of MCSA and Vibration result was making me confuse so much. - MCSA indicates rotor broken bars problem with high peaks at pole pass sidebands. - There is no symptom in vibration spectrum. We can see result in my attachment. Please give me your oppinion! Thank you! Regards,
Reply

Re: Rotor broken bars?

Dave Reynolds ·
To diagnose rotor bar problems in vibration spectrum: Identify actual running speed and subtract it from synchronous speed 1800-1775=25 rpm of slip, now multiply the slip rpm X the number of poles in the motor 4 poles x 25=100 cpm pole pass sidebands IF the motor truly has a rotor bar problem, then you should see the pole pass sidebands around 1x 2x 3x 4x 4x 5x rpm or some combination of the harmonics. Keep in mind your bin spacing on spectrum, you must have good resolution to see these...
Reply

Re: Rotor broken bars?

Panta ·
Lampard, like Dave said you must cut spectrum or Fmax. should be at 5-6 speed of motor to see good patern and good haystaks . At figure 6 it should be rotor bar pass frequency pick at 1470 Hz and one pick left like twice line frequency sideband . Good luck .
Reply

Re: Rotor broken bars?

Lampard Nguyen ·
Dear all, Thank you so much for your recommendations. I have just performed RIC (rotor influence check) for this motor. RIC profile indicates some erratic relate to rotor broken bar issue. I think that there is problem of rotor. It's a interesting case-study! Thank you! Best regards,
Reply

Re: Finish Mill Stand Gearbox

Monitor man ·
Originally Posted by Phil2425: I am seeing 1x impacting in waveform data from a gearbox. We have opened the box up to replace a faulty bearing. We inspected the gearsets and did not find any signs of broken or cracked gear teeth. I know that other stand and other mills have a 1x during operation. Does anyone else have any experience with this. If you have a cardon shaft check the u-joint cross can be damaged. There for the "clear" time signal
Reply

Re: Shaft Fracture Demineralized Pump

Dave Reynolds ·
The pictures showing the keyway, all the porosity, poor edges on key way, chipped metal
Reply

Re: Shaft Fracture Demineralized Pump

Hatop Hendra PS ·
So it's depend on speed? Not torsion walt? So what kind of coupling do you suggest for this application.
Reply

Re: Shaft Fracture Demineralized Pump

Walt Strong ·
I would not consider a "tyre" coupling for 3000 rpm even though the manufacturer rated it for that service. This is not to say it would be unsuitable for your application. Walt
Topic

Finish Mill Stand Gearbox

Phil2425 ·
I am seeing 1x impacting in waveform data from a gearbox. We have opened the box up to replace a faulty bearing. We inspected the gearsets and did not find any signs of broken or cracked gear teeth. I know that other stand and other mills have a 1x...
Reply

Re: Finish Mill Stand Gearbox

John from PA ·
What I see is an overall of 0.0641 in/sec pk, which is not alarming in itself, but I do see a crest factor of slightly over 4. Is this behavior something recent or has this been this way for some time? Any idea is there has been an upward trend of the crest factor? Can you take the gearbox out of service and inspect the teeth using a dye penetrant method? Audibly, does the gearbox have a pronounced "knocking".
Reply

Re: Finish Mill Stand Gearbox

Phil2425 ·
There is not an audible knock. You can just feel a 1x thud when operating. We changed spindle components and it got somewhat better. Just very curious as to what it is.
Reply

Re: Finish Mill Stand Gearbox

Phil2425 ·
The Crest Factor has always ran between 3 - 4.
Reply

Re: Finish Mill Stand Gearbox

John from PA ·
Is the behavior of the impacting in the waveform something recent? Or perhaps first time observed? In light of the overall amplitude of 0.06 I'd be inclined to just watch carefully. However, if that evidence of impacting in the waveform just suddenly started I would have some concerns. By the way, what are the speeds and tooth counts of this gearbox?
Reply

Re: Finish Mill Stand Gearbox

Bill Kilbey ·
Take some PeakVue readings, it may be much more clear.
Reply

Re: Finish Mill Stand Gearbox

Ramos_ ·
Looking at the TWF, there are 3-4 teeth that is creating modulation that is why they appear like as 1X peak sidebands on the FFT and also look like an impacting. Crest factor will also be increased as Pk is getting higher than RMS reading (CF = Pk/RMS), especially when there is impacting. For this case, some recommended actions can be: 1. John's suggestion is good if it's possible. I worked in Cement plant before and periodically we stopped cement ball mills and can do inspection. Boroscopic...
Reply

Re: Finish Mill Stand Gearbox

Phil2425 ·
I have been taking Demod data and there is no signs of impacting or defects in the high freq data.
Reply

Re: Finish Mill Stand Gearbox

Bill Kilbey ·
Can you post that DEMOD or PeakVue TWF data?
Reply

Re: Finish Mill Stand Gearboxes

Phil2425 ·
Here are the images. This data is taken in the vertical plane. Impacting is at the turning speed of the bottom pinion output shaft. This shaft has 2 gears on it. A 51T and a 28T gear. The 51T is the Bull that is driven by the input pinion from motor and the 28T mates up with a Top Pinion 28T and those drive the Rolls.
Topic

Finish Mill Stand Gearboxes

Phil2425 ·
I am seeing a 1x vibration in our Finish Mill Stand Gearboxes. I know that a broken or cracked gear tooth will cause this issue, however we have opened up a box and did not see ay signs of a cracked or broken gear. Some of our other stands...
Topic

Pole Pass Reading in Standard Route Readings

oju ·