Dear Sir ,

yes it is 2X of  Gear O.P shaft but what about the Fan readings , is not there provision to take Fan readings , i think fan directly mounted on out put shaft .

1. 4H to 4 V phase difference is 90 indicates Balancing problem .     But

2. 1A to 2A ,2H to 2V and  4A to 3A Phase difference is nearly 180 indicates misalignment .

as per the data i would suggest first to check & correct Machine train alignment then after you could check & Correct Fan balancing .If you have complete spectrum from Motor,G.B  and Fan ,please post .